Stenderd Fimne Line ComMctione
Incoming phone line and handset wiring is connectedto the main terminal
block(via a RJ31Xjack) asfollows(alsoseeFigure 4>
Term. 21: LocalHandset (TIP - Brown*)
Term. 22: LocalHandset (RING - Grafl)
Term. 23: Incoming Phone Line (TIP Green*)
Term. 24 IncomingPhone Line (RING Red*)
* Colorsofwiresin DirectConnectCord.
––i
E@E@iEl
Incoming
Handset
TelcaLine
21 22
23 24 2S
TERMINALS
ON CONTROL
> y - I,NciMiNGiE,co,,N,
r
C5
z
z
131x:;G
PREMISES
ml
~~+
I“IJACK
PHONES
1
I
“u
r
PLUG
I
Figure 4. Telephme Line Connections
We
Ilse AC T~
132U’I’F2 Wire the 132UTF2
transfomner to terminals 1 and 2 on the control board.
Seewking table belowfor wire gaugeto use.
Caution must be taken when wiring the transformer to the control panel to
guard against blowing the fuse inside the transformer (the fuse is non-
replaceable).
4300 If you are going to use a 4300 transformer interface (required if Powerline
Carrier devices are going to be used), connect the 4300 transformer’s
terminals as follows:
a. Terminals 1, 3 (AC), and 2 (Ground) to ccmtiolboard terminals 1, 2, and
25, respectively(seeFigure 5). Seetable belowfor wire gaugeto use.
WIRING TABLE
Distanceof Transformer
WireGauge
Fromthe ControlPanel
To Use
up to50feet
#20
50-100feet
#18
100-250feet
#16
-15-