Vista Ademco -10SE Anleitung zur Fehlerbehebung Seite 72

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 100
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 71
72–
10 INPUT S/N: L
Axxx xxxx
5. This prompt is displayed when the system has found the next zone which
needs to be enrolled. The system will respond to the first serial number
transmitted after the [
*
] key on the keypad is pressed. A serial number
may be enrolled by one of two methods:
a) Enter the 7 digit serial number printed on the transmitter
or
b) Activate the transmitter by faulting or restoring the input you wish to
use for that zone (e.g., press a button, open or close a door, etc.).
If you do
not
wish to enroll the zone displayed, press the [#] key on the
keypad or the upper right-hand button on the program tool (a long beep will
be heard to verify). The following prompt will appear:
10 LEARN S/N?
0 = NO, 1 = YES 0
To enroll now, enter "1" (YES). If "0" (NO) is entered, the following prompt
will appear if a program tool has already been programmed:
ENTER ZN NUM.
(00 = QUIT) 12
Zone Number Entered
Enter the next zone number to be enrolled (e.g., zone 12). The system will
search for that zone and will display the prompt shown in the beginning of
step 5. If you wish to exit the enroll mode completely, enter 00 and press
[
*
].
10 INPUT S/N:L
A 022-4064 3
Serial # Loop #
The system will enroll the serial number of the first transmitter heard, add
the loop number entered to this serial number, display the serial and loop
numbers, and cause the keypad to beep twice.
If the serial and loop number combination is already present in the system, a
single long beep will be heard from the keypad. If this happens, the system
will not display the serial number, but will wait for a transmission from another
transmitter or transmitter loop input.
6. The system will then enter an optional confirmation mode so that the
operation of the actual programmed input can be confirmed. Activate the
loop input or button that corresponds to this zone. We recommend that
you confirm the programming of every transmitter before
proceeding to the next zone.
Seitenansicht 71
1 2 ... 67 68 69 70 71 72 73 74 75 76 77 ... 99 100

Kommentare zu diesen Handbüchern

Keine Kommentare