Vista Ademco -10SE Anleitung zur Fehlerbehebung Seite 80

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 100
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 79
80–
Keypad Functions
General Information Note that if you enabled QUICK ARM for the partition (field
*
21), the [#] key can
be pressed instead of entering the partition's security code, for any of the arming
procedures (Away, Stay, Instant, Maximum, etc.). The security code is alway
s
required, however, when disarming the system.
The keypad allows the user to arm and disarm the system, and perform other
system functions, such as bypassing zones, and display zone descriptors. Zone
and system conditions (alarm, trouble, bypass) are displayed in the Display
Window.
When an alarm occurs, keypad sounding and external sounding will occur, and
the zone(s) in alarm will be displayed on the keypad. Pressing any key will
silence the keypad sounder for 10 seconds. Disarming the system will silence
both keypad and external sounders. When the system is disarmed, any zones
that were in an alarm condition during the armed period will be displayed
(memory of alarm). To clear this display, simply repeat the disarm sequence
(enter the security code and press the OFF key) again.
The keypads also feature chime annunciation, and 3 panic key pairs, or individual
panic keys (depending on keypad type – see
Panic Keys
below), for silent,
audible, fire or personal emergency alarms. These keys can notify the central
station of an alarm condition, if that service is connected.
Arming Functions The following is a brief list of system commands. For detailed information
concerning system functions, refer to the User's Manual.
Disarmed, Not Ready ........... Before arming, the system must be in the READY
condition (all zones must be intact). If the "NOT
READY" message appears, press the READY [
*
]
key to display faulted zones.
Arming Away ........................ Enter code + AWAY [2].
Arming Stay .......................... Enter code + STAY [3].
Arming Instant ...................... Enter code + INSTANT [7].
Arming Maximum ................. Enter code + MAXIMUM [4].
Disarming .............................. Enter code + OFF [1].
Bypassing Zones ................. Enter code + BYPASS [6] + zone number(s).
Forced (Quick) Bypass........ (If enabled) To automatically bypass all faulted
zones, use the "Quick Bypass" method:
Enter code + BYPASS, then wait for all open
zones to be displayed. Arm when display
indicates “bypass” and “ready to arm”.
Chime Mode .......................... Enter code + CHIME [9].
To turn chime off, enter code + CHIME again.
SUMMARY OF ARMING MODES
Features for Each Arming Mode
Arming
Mode
Exit
Delay
Entry
Delay
Perimeter
Armed
Interior
Armed
AWAY Yes Yes Yes Yes
STAY Yes Yes Yes No
INSTANT Yes No Yes No
MAXIMUM Yes No Yes Yes