Panic Keys
Rela#Powdine Carrier
(if used)
42S5 Voice
Module
(if
used)
Esit Error AlaraI
-b
(if programmed)
There are three panic key pairs or (on some keypads) lettered keys that, if
programmed, can be used to manually initiate alarms and send a report to
the central station.
Each can be individually programmedfor 24hour Silent,Audible, Personal or
Fire Emergency responses.The panic function is activatedwhen both keys of
the appropriate key pair are pressed at the same time, or the appropriate
lettered key is pressedfor at least 2 seconds.
The panic fimctions are identified by the systemas follows
Keys
Displayed as Zone
Notes:
[11& [*I, or [Al
95
.
Keys [A], [B], [C] are not on all
[*I & [#l, or OX
keypads.
99
Key [D], if present, is not active
[31& [#l, or [Cl
96
here.
a
Zmportant: For the Silent Panic functions to be of practical value, the
systemmust be connectedto a centralstation.
If relay outputs (via a 4204, or 4229), or Powerline Carrier devicesare used,
two keypad entries available to the user are included. They can manually
activateor deactivatethe device(s)for start@ or stoppingsomeaction,such
asturning lights on or off, etc.
Thesekeypad enties are:
Security Code + [#] + [71 + Device # activates(starts)that device.
Security Code + [#] + [8] + Device # de-activates(stops)that device.
Refer to the separate instructions supplied with the Voice Module for
information concerningits operating procedures.
Note: The Voice Module cannot be used to add user codesin this system.
User codesmust be added by usimza wired kevoad.
A display of “CANCELED ALARM?’
or “CA” and a zone indication
will
appear if an exit or interior zone contained a fault during closing at
the time the ezit delay ended (e.g.,exit door left open),
but the system was
disarmed during the entry delay time. The alarm
sounder and keypad
sound continuously, but stop when the system is disarmed. No message
Willbetr ansmittedto the central station.
A display of “EXIT
ALARM” or “EAt’ and a zone indication will
appear if an exit or interior zone contained a fault during closing at the
time the exit delay ended,
but the system was NOT disarmed during the
entry delay time. The alarm
sounder and keypad sound continuously until
the system is disarmed (or timeout occurs). An “exit alarm” messageis
sent to the central station.
The “EXIT ALAFtNF’ display, etc. will also result if an alarm from an
exit or interior zone occurs within two minutes after the end of an exit
delay.
In any of the abovecases,use a secondOFF sequence(codeplus OFF key) to
clearthe display.
-102-