Rek@Powerlime Carrier Device Basks
Relays and Powerline Carrier devices (ex. X-10 brand devices) are
programmable switchesthat canbe used to perform many difRerentfunctions.
They can be used to turn lights on and off, control sounders, or for status
indications. In this system,each devicemust be programmed as to how to
act (ACTION), when to activate (START), and when to deactivate (STOP).
Each of these is describedbelow,and in the progr
axnmingprocedure for *8O
and *81 interactivemodesthat me provided at the end of this section.
The control supports a total of 8 output devices in the following
con.@urations:
One 4204 relay module (4 relays) and 4 PowerlineCarrier devices.
One 4229 zonehelay module (2 relays) and 6 PowerlineCarrier devices.
c Up to 8 Powerline Carrier devices(8 minus the number of output relays
used).
The 4204 and 4229 modules provide Form C (normally open and normally
closed)contacts. Powerline Carrier devicesare controlled by signals sent
through the electrical wiring at the premises via a 4300 transformer.
Therefore, if using Powerline Carrier Devices, a 4300 transformer
must be
usedin placeof the regular systemtransformer.
In *8O and *81 interactive modes, a series of keypad prompts wdl request
entries for progr
amming of the Relay outputs and/or Powerline Carrier
devicesused in the system. Refer alsoto “OUTPUT RELAYS/POWERLINE
CARRIER DEVICES WORKSHEET FOR *8O AND *81 INTERACTIVE
MODES” in the blank programming
g form.
4204 and 4229 Reky Modules
4204/4229 -p
The 4204
or 4229 unitcan be mounted either remotelyor in the controlpanel.
The following stepsshouldbe taken to properly setup the 4204 or 4229:
1. Connect the 4204/4229 to the control’s Partition 1 remote keypad
terminals (4-7),
using the connectorsupplied with the 4204 and 4229.
Use standard 4conductor twistedcablefor long wiring runs.
2. Set the 4204/4229’s D~ switch for a device address of ‘l” (switch 2
“OFF” md switches3, 4, 5 “ON”). Switch 1 determines tie tit’s cover
tamper response(“ON
= disabled,“OFF”= enabled).
3. Connect the desired field wiring to the unit’s relay contactterminals.
Supervision
c 4204
and 4229 modules are supervised against removal. CHECK and
zone 09 will be displayed if a module is disconnectedfkom the control’s
txxminals
(4,5,6, & 7).